Soumyen Mukherjee, President of Sova Solar defines PID and how to prevent photovoltaic PID.

The term Potential Induced Degradation (PID) was first introduced in the English language in a published study by S. Pingel and co-workers in 2010. It was introduced as a degradation mode resulting from voltage potential between the cells in the photovoltaic module and ground. Research in this field was pioneered by the Jet Propulsion Laboratory, focusing primarily on electrochemical degradation in crystalline silicon and amorphous silicon photovoltaic modules.

It is worth mentioning that, Sova Solar Ltd is associated with a team of IIT Kharagpur lead by Prof. Jatin Roy who has wide vista of knowledge on PID. In his research work he has published many vital issues in this regard.

What is PID?
The phenomenon described here only occurs in modules with cells made of crystalline silicon. If the modules have a negative potential to earth in operation, there is an equally high negative voltage between the cells of the photovoltaic (PV) module and the aluminium frame, which is earthed for safety reasons. The effect is stronger, the closer the module is to the negative pole of the PV array, as the potential there (and thus the voltage between cells and the aluminium frame) can reach more than half the amount of the array voltage. As a result, electrons from the materials used in the PV module can separate, follow this electric field and finally flow out via the aluminium frame. The result is an increasing charge (polarisation) of the module, which adversely changes its characteristic curve and thus its power unless countermeasures are taken.

The characteristic curve of a PV module in the original state and during the degradation process a decreasing slope with a virtually unchanged open-circuit voltage and short-circuit current, while the maximum power (MPP) decreases by 30 per cent or more, is typical. The electric charge of the PV module is so critical because of the way solar cells work. The PV effect is based on the combination of two different semiconductor materials to establish an internal electric field by exchanging charges. It is this field that causes the electrons freed by light energy to move from their location and flow past the contacts as electric current. Additional load carriers can considerably interfere with this effect, causing a significant loss of power. However, it has been found that this polarisation can generally be reversed. Accordingly it is not an irreversible effect such as corrosion and normal aging-related deterioration. The term PID was first used in the 2010 publication by module manufacturer Solon, which examined the phenomenon in detail.

Advertising

EPR Android App Banner

IEC TS 62804-1:2015(E)
IEC TS 62804-1:2015(E) defines procedures to test and evaluate the durability of crystalline silicon PV modules to the effects of short-term high-voltage stress including PID. Two test methods are defined that do not inherently produce equivalent results. They are given as screening tests; neither test includes all the factors existing in the natural environment that can affect the PID rate. The methods describe how to achieve a constant stress level. The testing in this technical specification is designed for crystalline silicon PV modules with one or two glass surfaces, silicon cells having passivating dielectric layers, for degradation mechanisms involving mobile ions influencing the electric field over the silicon semiconductor, or electronically interacting with the silicon semiconductor itself. Sova Solar Ltd. is certified with IEC 62804 and they are planning to get their module tested from Fraunhofer University.

How to take protection
The PID negative effect can be completely prevented if an inverter is used with the possibility of grounding (or effectively grounding) the positive or negative pole. This is possible if the inverter is galvanically isolated, e.g. using a transformer, if specially designed transformer less inverter topologies are used, or by altering the electric grid potential to ground. Which pole must be grounded, is clarified with the solar module manufacturer.

Authored by:

Soumyen Mukherjee
President
Sova Solar Limited

Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

Android App
Android App
EPR EMagazine November 2024
eMagazine November 2024
eMagazine November 2024

Events

Auto EV India
Auto EV India
Global Sustainability Expo & Conference
Global Sustainability Expo & Conference
Elecxpo
Elecxpo
India Smart Utility Week
India Smart Utility Week
RenewX
RenewX

Our Sponsors

CPRI
CPRI
Wika
Wika
Mahindra Powerol
Mahindra Powerol
NangalaWala
NangalaWala
Ramelex
Ramelex
Ambionics India
Ambionics India
Vasundhara Earthing
Vasundhara Earthing
Voltaredox
Voltaredox
Jayashree
Jayashree
Rayzon Solar Pvt Ltd
Rayzon Solar Pvt Ltd
Om Technical Solutions
Om Technical Solutions
Akansha
Akansha
NBC Bearings
NBC Bearings
Harting
Harting
Doble Engineering
Doble Engineering
Kusam Meco
Kusam Meco
Nirmal
Nirmal
Apar Industries
Apar Industries
Aramco Asia
Aramco Asia
Fluke
Fluke
Emka India Panel Accessories
Emka India Panel Accessories
KEI Industries Limited
KEI Industries Limited
Meco Instruments Pvt Ltd
Meco Instruments Pvt Ltd
Godrej Boyce
Godrej Boyce
Icon Solar-En Power
Icon Solar-En Power
ZIEHL ABEGG
ZIEHL ABEGG
Novasys
Novasys
Ramanuj Industries
Ramanuj Industries
Testo India
Testo India
Paras Wires
Paras Wires
Dirak India
Dirak India
Fronius India
Fronius India
Gloster Cables Limited
Gloster Cables Limited
K-Lite Industries
K-Lite Industries
Newtech Switchgear
Newtech Switchgear
Rectifiers & Electronics
Rectifiers & Electronics
Elev8 Lift
Elev8 Lift
Power trac Group
Power trac Group
flir system
flir system
Omicron
Omicron
Dhash
Dhash
CAT
CAT
Electrical Research Development Association
Electrical Research Development Association
Schneider Electric
Schneider Electric
Triveni Turbine ltd
Triveni Turbine ltd
Kirloskar Pumps
Kirloskar Pumps
Polycab
Polycab
Electrotherment
Electrotherment
Aeron Composite Pvt Ltd
Aeron Composite Pvt Ltd
Powerica LTD
Powerica LTD