Promonique
Promonique
EPR Subscription Banner
EPR Subscription Banner
Promonique Banner
Promonique Banner
Home » Power Brand » Utilising Online Dissolved Gas Analysis (DGA) for enhanced end-of-life management of ageing power transformers

Utilising Online Dissolved Gas Analysis (DGA) for enhanced end-of-life management of ageing power transformers

By EPR Magazine Editorial December 21, 2023 4:01 pm

Utilising Online Dissolved Gas Analysis (DGA) for enhanced end-of-life management of ageing power transformers
.

Ensuring the health of power transformers is paramount, as sudden breakdowns are not only costly but also time-consuming to repair.

Ensuring the health of power transformers is paramount, as sudden breakdowns are not only costly but also time-consuming to repair. Vigilant monitoring becomes a crucial investment, offering a preemptive strike against potential issues. Early detection of problems, whether related to overloading, insulation deterioration, or electrical disturbances, translates to significant savings in both time and money. Proactive maintenance allows for strategic planning, preventing unexpected disruptions in power supply. From planned overloads to inadequate maintenance, keeping a watchful eye on transformers serves as a safeguard, ensuring a seamless and uninterrupted flow of power. In essence, timely checks act as a financial and operational safety net, averting unforeseen troubles.

Solution

The Transformer Monitoring System Dissolved Gas Analyser TM8 is a sophisticated device designed for comprehensive monitoring and analysis of dissolved gases within transformer oil. As a critical component of transformer health assessment, this analyser plays a pivotal role in predictive maintenance strategies, enabling early detection of potential faults or issues within power transformers.

Key Features and Functions

Gas Detection Technology: The TM8 employs state-of-the-art sensors or probes immersed in the transformer oil to detect and quantify various gases dissolved within. These gases are indicative of different types of electrical and thermal faults that can occur within the transformer.

Gas Types and Fault Indicators: It analyses a range of gases such as methane, ethane, ethylene, acetylene, hydrogen, carbon monoxide, and others. Each gas and their respective ratios can provide vital information regarding different types of faults occurring in the transformer, such as overheating, partial discharge, arcing, insulation degradation, or ageing issues.

Advertising

EPR Android App Banner

Continuous Monitoring and Trend Analysis: The TM8 continuously monitors gas levels within the oil over time. By analysing trends and deviations in gas concentrations or ratios, it assists in identifying potential emerging issues or degradation within the transformer’s insulation and windings.

Alarm Systems and Notifications: The system is equipped with configurable alarm thresholds. When gas levels surpass predefined limits or exhibit irregular ratios, it triggers alerts, notifying operators or maintenance personnel. These notifications prompt further investigation or action to prevent potential transformer failures.

Diagnostic Tools and Reporting: Advanced diagnostic tools and software embedded in the TM8 facilitate data interpretation. It generates detailed reports, trends, and actionable recommendations for maintenance teams, aiding in the identification of specific transformer issues and planning targeted maintenance interventions.

Integration and Connectivity: The TM8 likely supports integration with broader transformer monitoring platforms and systems. It may utilise multiple communication protocols for seamless connectivity, allowing centralised monitoring, data analysis, and remote access capabilities.

In conclusion, effective monitoring of power transformers is crucial to prevent unexpected breakdowns, ensuring reliability and minimising costs. Utilising online Dissolved Gas Analysis (DGA) through advanced systems like the Transformer Monitoring System Dissolved Gas Analyser TM8 allows for early detection of potential faults, providing continuous monitoring, alarms, and detailed reporting. This proactive approach enhances the overall management of aging transformers, ensuring a smooth and reliable power supply.


Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

Tags: Power Brand
Android App
Android App
EPR EMagazine November 2024
eMagazine November 2024
eMagazine November 2024

Events

Auto EV India
Auto EV India
Global Sustainability Expo & Conference
Global Sustainability Expo & Conference
Elecxpo
Elecxpo
India Smart Utility Week
India Smart Utility Week
RenewX
RenewX

Our Sponsors

CPRI
CPRI
Wika
Wika
Mahindra Powerol
Mahindra Powerol
NangalaWala
NangalaWala
Ramelex
Ramelex
Ambionics India
Ambionics India
Vasundhara Earthing
Vasundhara Earthing
Voltaredox
Voltaredox
Jayashree
Jayashree
Rayzon Solar Pvt Ltd
Rayzon Solar Pvt Ltd
Om Technical Solutions
Om Technical Solutions
Akansha
Akansha
NBC Bearings
NBC Bearings
Harting
Harting
Doble Engineering
Doble Engineering
Kusam Meco
Kusam Meco
Nirmal
Nirmal
Apar Industries
Apar Industries
Aramco Asia
Aramco Asia
Fluke
Fluke
Emka India Panel Accessories
Emka India Panel Accessories
KEI Industries Limited
KEI Industries Limited
Meco Instruments Pvt Ltd
Meco Instruments Pvt Ltd
Godrej Boyce
Godrej Boyce
Icon Solar-En Power
Icon Solar-En Power
ZIEHL ABEGG
ZIEHL ABEGG
Novasys
Novasys
Ramanuj Industries
Ramanuj Industries
Testo India
Testo India
Paras Wires
Paras Wires
Dirak India
Dirak India
Fronius India
Fronius India
Gloster Cables Limited
Gloster Cables Limited
K-Lite Industries
K-Lite Industries
Newtech Switchgear
Newtech Switchgear
Rectifiers & Electronics
Rectifiers & Electronics
Elev8 Lift
Elev8 Lift
Power trac Group
Power trac Group
flir system
flir system
Omicron
Omicron
Dhash
Dhash
CAT
CAT
Electrical Research Development Association
Electrical Research Development Association
Schneider Electric
Schneider Electric
Triveni Turbine ltd
Triveni Turbine ltd
Kirloskar Pumps
Kirloskar Pumps
Polycab
Polycab
Electrotherment
Electrotherment
Aeron Composite Pvt Ltd
Aeron Composite Pvt Ltd
Powerica LTD
Powerica LTD