Promonique
Promonique
Rayzon
Rayzon
EPR Subscription Banner
EPR Subscription Banner
Home » Elecrama » Elecrama 2018 » PR electronics 9106B HART transparent repeater

PR electronics 9106B HART transparent repeater

By March 8, 2018 11:50 am IST

PR electronics 9106B HART transparent repeater
.

What is “HART”?

The HART protocol is a low speed, digital communications scheme that is carried on a 4…20 mA current signal. Since 4…20 mA loops are commonly used in industry, the HART protocol is easy to implement, easy to use, and fairly easy to troubleshoot. 4…20 mA devices that communicate via HART are popular in many industries, including the chemical and petrochemical industries.

What does “HART transparent” mean?
The 9106B HART transparent repeater can safely excite and measure standard or HART-enabled transmitters, located in zone 0 / Division 1 hazardous locations. The 9106B is HART transparent, so digital messages between a HART field transmitter in the hazardous area a HART master located in the safe area will pass through the 9106B without any problems.

Why use the 9106B?
When connected to a certified field transmitter, the 9106B can provide an “intrinsically safe” measurement of the transmitter’s 4…20 mA signal and HART protocol. Thus, a HART master located in the safe area can now safely measure the field transmitter without risk of an explosion in the hazardous area. The 9106B is a barrier which allows standard devices –like a HART master, to safely measure field transmitters located a hazardous area.

Can the 9106B be used with standard, (non-HART), current transmitters?
Yes, the 9106B can be used with HART or standard, (non-HART), 4…20 mA current transmitters.

Can the two channel 9106B measure one field transmitter and output two isolated HART transparent 4…20 mA signals?
Yes.

Advertising

EPR Android App Banner

Can the 9106B measure active or passive current signals?
Yes.

Can the 9106B can output active or passive current signals?
Yes.

What is the difference between active and passive current signals?
A voltage source must be present in order to create a current flow. A device that creates an “active” current signal contains the voltage source within the device. A device that creates a “passive” current signal does not have its own voltage source. Thus, no current flow will occur until an external voltage source is connected to the device signal wiring. Some devices create or require an active current signal, and other devices create or require a passive current signal. The 9106B input and output works with either active or passive current, making it usable with all 4… 20 mA devices on the market.

Contact

Toshniwal Hyvac Pvt Ltd
267, Kilpauk Garden Road, Chennai – 600 010
Tele: +91-44-26448983 / 8558
Email: sales@toshniwal.net I www.toshniwal.net

Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

Android App
Android App

Events

RenewX
RenewX
Wiretech 2025
Wiretech 2025
Power Gen
Power Gen
World Utilities Congress
World Utilities Congress
India Green Energy Expo
India Green Energy Expo

Our Sponsors

Wika
Wika
Ramelex
Ramelex
Rayzon Solar Pvt Ltd
Rayzon Solar Pvt Ltd
Akansha
Akansha
Andritz Hydro Pvt Ltd
Andritz Hydro Pvt Ltd
Vyoma Switchgear
Vyoma Switchgear
Skipper Limited
Skipper Limited
Joint Well
Joint Well
Kp Group
Kp Group
Credence Solar
Credence Solar
Grew Solar
Grew Solar
Nirmal
Nirmal
Meco Instruments Pvt Ltd
Meco Instruments Pvt Ltd
Novasys
Novasys
HPL Electric Power
HPL Electric Power
Sun Bond
Sun Bond
Supremesolar
Supremesolar
Vsole Solar
Vsole Solar
Elev8 Lift
Elev8 Lift
Power trac Group
Power trac Group
Omicron
Omicron
Ganz Electric
Ganz Electric
Eplan
Eplan
Aeron Composite Pvt Ltd
Aeron Composite Pvt Ltd
Eaton
Eaton
A-1 ELECTRICALS
A-1 ELECTRICALS
Ashone Technologies
Ashone Technologies
MENNEKES Electric India
MENNEKES Electric India
PRAMA HIKVISION INDIA
PRAMA HIKVISION INDIA
Motwane Manufacturing
Motwane Manufacturing
Sun Cables
Sun Cables