Kusam-Meco transducers
By EPR Magazine Editorial October 5, 2018 2:30 pm
By EPR Magazine Editorial October 5, 2018 2:30 pm
Kusam-Meco transducers are used for accurate measurement of electrical parameters, remote monitoring and automation, suitable for sinusoidal and true RMS inputs, with high accuracy (0.2 per cent), high dielectric strength 2.6 KV AC/ min, between input/output/power case, separate AC or DC auxiliary supply or built in (self-powered), suitable for single phase as well as 3-phase balanced or unbalanced load. Precision measurement even for distorted wave etc.
The types of transducer available are AC current transducer, AC voltage transducer, Watt or Var transducer, combined Watt and Var transducer, Watt HOUR or Var hour transducer, combined Watt and Watt HOUR or Var and Var hour transducer and power factor transducers.
• Kusam-Meco AC current transducer accepts input current upto 0 ~ 10 A AC. Single or dual output is available, 4 ~ 20 mA DC. Various types of inputs such as 1unit avg., 3unit avg. conversion, 1 unit True RMS and 3 unit true RMS conversion are available. The output is 4~20 mA dc.
• Kusam-Meco AC Voltage transducer has input voltage upto 600 V AC, output is 4~ 20 mA DC. This transducer has inputs of 1unit avg., 3unit avg., 1 unit true RMS conversion, 3 unit true RMS conversion.
• Kusam-Meco Watt or Var transducer is available for 1 phase 2 wire, 3 phase 3 wire, or 3 phase 4 wire circuits. Input voltage is 220 V; (L-N) input current is 5A, frequency is 50 Hz, and output is 4 ~ 20mA DC. These transducers are available for uni-direction and bi-direction measurements.
• Kusam-Meco Watt and Var transducer combined can be connected for 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire circuit, input voltage is 220 V (L-N) input current is 5 A, frequency is 50 Hz, output is 4 ~ 20 mA and this transducer is available in Uni- direction measurement.
• Kusam-Meco Watt hour or Var hour transducer are suitable for use in 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire circuit, input voltage is 220 V (L-N), input current is 5 A, frequency is 50 Hz output is WH / 10 pulse. and QH / 10 pulse. Watt hour uni-direction, and Watt hour bi-direction and Var hour bi-direction are available.
• Kusam-Meco Watt / Watt hour or Var / Var hour transducer are suitable for use in 1 phase 2 wire, 3 phase 3 wire, 3 phase 4 wire circuit, input voltage is 220 V (L-N), input current is 5A, frequency is 50 Hz, W (Var) output is 4 ~ 20 mA, and WH (Var H) output is WH / 10 pulse and QH / 10 pulse Watt / Watt hour uni-direction, Watt / Watt hour bi-direction and var / var hour bi-direction transducer are available.
We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.