ABB capacitor duty contactor

By March 4, 2020 10:59 am IST

ABB capacitor duty contactor
.

UA30..RA 3-pole contactors for capacitor switching can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energised when the contactors are making. Their electrical durability is 2,50,000 operating cycles for Ue< 500 V and 1,00,000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energisation of the capacitor bank. Their connection also ensures capacitor pre-charging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to dampen the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design.

Main poles and auxiliary contacts: Three main poles, one built-in auxiliary contact
Control circuit: AC operated with laminated magnet circuit
Accessories: A wide range of accessories is available.

Capacitor transient conditions
In low-voltage industrial installations, capacitors are mainly used for reactive energy correction (raising the power factor). When these capacitors are energised, over-currents of high amplitude and high frequencies (3-15 kHz) occur during the transient period (1-2 ms). The amplitude of these current peaks, also known as “in rush current peaks”, depends on the following factors:

    Advertising

    EPR Android App Banner

    The network inductances
  • The transformer power and short-circuit voltage
  • The type of power factor correction

Application
The UA..RA contactors can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances.

For more information, visit:
R.SANGHAVI MERCANTILE PVT. LTD.
Website: www.abbdealer.com

Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

Android App
Power Talk
webinar

Events

Renewable Energy India (REI)
ELAsia 2026

Our Sponsors

Kimbal
Wika
Transwind Tech
Panasonic Life Solutions India Pvt Ltd
Rayzon Solar Pvt Ltd
Andritz Hydro Pvt Ltd
Joint Well
NBC Bearings
Allied Power Solutions
Apar Industries
Ravin Group
Meco Instruments Pvt Ltd
Godrej Boyce
Lucy Electric
Novasys
BRACO ELECTRICALS PVT.LTD
Guru Teg Bahadur Metal Works
phoenix Contact Pvt Ltd
Myraid Industrial Solutions LLP
Sunbond Energy Pvt Ltd
KPI Green Energy Ltd
Balaji Switchgears
S K Industrial
Rectifiers & Electronics
Synthesis Winding Technologies Pvt Ltd
flir system
Omicron
DEIF
Eplan
EMR
Kirloskar Pumps
Ultra Electric India
Polycab
Electrotherment
Aeron Composite Pvt Ltd
Delta
A-1 ELECTRICALS
MENNEKES Electric India
PRAMA HIKVISION INDIA
Ultra Electric India